Source[<N>]][:Trace]:Data:dac16 - Rigol DG800 Pro Series Programming Manual

Function/arbitrary waveform generator
Hide thumbs Also See for DG800 Pro Series:
Table of Contents

Advertisement

Description
Sets or queries the sweep time for the specified channel.
Parameter
Name
<n>
<time>
<lim_set>
<lim_query>
Remarks
The maximum value of <time> is limited by the sweep type, start/stop hold
time, trigger source, and return time.
Return Time + Stop Hold Time.
-
-
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns the sweep time in scientific notation. For example, the query
might return +5.000000000000000E+00, indicating that the sweep time is 5 s.
Examples
:SOURce1:SWEep:TIME 5 /*Sets the sweep time to 5 s for CH1.*/
:SOURce1:SWEep:TIME? /*Queries the sweep time for CH1. The query
returns +5.000000000000000E+00.*/
3.11.18
[:SOURce[<n>]][:TRACe]:DATA:DAC16
Syntax
[:SOURce[<
Description
Downloads the Arb data to the volatile memory of the specified channel.
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Type
Discrete
Real
Discrete
Discrete
Linear Sweep: internal trigger source,
external trigger source,
T
Log/Step Sweep:
≤ 500 s.
P
n >]][:TRACe]:DATA:DAC16 < type >,< flag >,< data >
Range
{1|2}
1 ms to 250,000 s
{MINimum|MAXimum|DEFault}
{MINimum|MAXimum}
T
= Sweep Time + Start Hold Time +
P
T
+ 1 ms ≤ 8,000 s; manual/
P
T
≤ 250,000 s.
P
DG800 Pro/DG900 Pro Programming
Command System
Default
1
1 s
-
-
Guide
155