Command System
:OUTPut1:LOAD? /*Queries the output impedance for CH1 output
connector. The query returns 9.9E+37.*/
3.10.3
:OUTPut[<n>]:POLarity
Syntax
:OUTPut[<
:OUTPut[<
Description
Sets or queries the output polarity for the specified channel.
Parameter
Name
<n>
<polarity>
Remarks
The output polarity sets the signal on the output connector to normal (NORMal)
or inverted (INVerted). In Normal mode, the instrument outputs a normal
waveform; in Invert mode, the instrument inverts the waveform and then
outputs the inverted waveform.
The waveform is inverted relative to the offset voltage. The offset voltage
remains unchanged when the waveform is inverted. The sync signal related to
the waveform is not inverted.
When [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns NORM or INV.
Examples
:OUTPut1:POLarity NORMal /*Sets the CH1 output polarity to Normal.*/
:OUTPut1:POLarity? /*Queries the CH1 output polarity. The query
returns NORM.*/
3.10.4
:OUTPut[<n>][:STATe]
Syntax
:OUTPut[<
:OUTPut[<
DG800 Pro/DG900 Pro Programming
Guide
56
n >]:POLarity < polarity >
n >]:POLarity?
Type
Discrete
Discrete
n >][:STATe] < state >
n >][:STATe]?
Range
{1|2}
{NORMal|INVerted}
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Default
1
NORMal