Programming Overview
The vertical bar is used to separate multiple parameters. When using the
command, you must select one of the parameters.
3. Square Brackets [ ]
The contents in the square brackets can be omitted.
4. Angle Brackets < >
The parameter enclosed in the angle brackets must be replaced by an effective
value.
Parameter Type
1. Bool
The parameter can be set to ON, OFF, 1, or 0. For example,
:SYSTem:BEEPer:STATe <
:SYSTem:BEEPer:STATe?
Wherein, <
2. Discrete
The parameter can be any of the values listed. For example,
:SYSTem:PSTatus <
:SYSTem:PSTatus?
Wherein,
sat > can be set to DEFault|OPEN.
- <
- The query returns an abbreviated form: DEF or OPEN.
3. Integer
Unless otherwise specified, the parameter can be any integer (NR1 format) within
the effective value range.
CAUTION
Do not set the parameter to a decimal; otherwise, errors will occur.
For example,
[:SOURce[<
Wherein, <
returns an integer ranging from 2 to 1024.
4. Real
The parameter can be any real number within the effective value range, and this
command accepts parameter input in decimal (NR2 format) and scientific notation
(NR3 format). For example,
DG800 Pro/DG900 Pro Programming
Guide
4
bool >
bool > can be set to {{1|ON}|{0|OFF}}. The query returns 1 or 0.
sat >
n >]]:SWEep:STEP {< step >|< lim >}
step > can be set to an integer ranging from 2 to 1024. The query