Command System
Remarks
Enabling/disabling the Sequence function for one channel also enables/disables the
Sequence function for the other channel.
Return Format
The query returns 0 or 1.
Examples
:SOURce1:FUNCtion:SEQuence:STATe ON /*Enables the Sequence
function for CH1.*/
:SOURce1:FUNCtion:SEQuence:STATe? /*Queries whether the Sequence
function is enabled for CH1. The query returns 1.*/
3.11.8.17
[:SOURce[<n>]]:FUNCtion:SQUare:DCYCle
Syntax
[:SOURce[<
[:SOURce[<
Description
Sets or queries the duty cycle percentage of square wave for the specified channel.
Parameter
Name
<n>
<percent>
<lim_set>
<lim_query>
Remarks
Duty cycle represents the amount of time per period that the square wave is at
a high level.
Sending
setting and sets the duty cycle to 50%.
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns the square duty cycle in scientific notation. For example, the query
might return +4.500000000000000E+01, indicating that the square duty cycle is
45%.
DG800 Pro/DG900 Pro Programming
Guide
116
n >]]:FUNCtion:SQUare:DCYCle {< percent >|< lim_set >}
n >]]:FUNCtion:SQUare:DCYCle? [< lim_query >]
Type
Range
Discrete
{1|2}
Real
0.01% to 99.99%
Discrete
{MINimum|MAXimum|DEFault}
Discrete
{MINimum|MAXimum}
[:SOURce[<n>]]:APPLy:SQUare
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
overwrites the current duty cycle
Default
1
50%
-
-