Nortel DMS-100 Series Replacement Procedures page 545

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

14
Post the faulty DCH card (NTBX02) by typing
>POST dch_no
and pressing the Enter key.
Table DCHINV details the physical P-side link, which maps the logical DCH
number to the physical location.
15
Busy the link to the faulty DCH card by typing
>BSY dch_no
and pressing the Enter key.
where
dch_no
is one of the cards with ports connected to the busied unit
At the equipment frame
16
Repeat steps 14 and 15 for each DCH card (NTBX02) with ports connected
to the busied unit.
17
Replace the faulty NTBX02 card using the common replacing a card
procedure in this document.
At the MAP terminal
18
Use the following information to determine the next step.
If you were directed here from
alarm clearing procedures
other
19
Load the replaced DCH card by typing
>LOADPM
and pressing the Enter key.
If load
passed
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the frame supervisory
panel (FSP). This protects the equipment against damage
caused by static electricity.
Do
step 24
step 19
Do
step 20
NTBX02
in an SMA
(continued)
1-513