Nortel DMS-100 Series Replacement Procedures page 438

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-406 XPM card replacement procedures (continued)
NTBX01
in an RSC-S (PCM-30) Model A RCO2
14
15
16
17
18
19
20
297-8021-547 Standard 14.02 May 2001
Use the following information to determine where to proceed.
If LOADPM
passed
failed
Test the inactive unit by typing
>TST UNIT rco2_unit_no
and pressing the Enter key.
where
rco2_unit_no
is the number of the RCO2 unit loaded in step 13
Use the following information to determine where to proceed.
If TST
passed
failed
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
Return the inactive RCO2 unit to service by typing
>RTS UNIT rco2_unit_no
and pressing the Enter key.
where
rco2_unit_no
is the number of the RCO2 unit tested in step 15
Use the following information to determine where to proceed.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
(continued)
Do
step 15
step 23
Do
step 17
step 22
Do
step 22
step 18
Do
step 20
step 24