1-814 XPM card replacement procedures (continued)
NTEX54
in an RSC LCM
At the MAP terminal
23
24
25
26
297-8021-547 Standard 14.02 May 2001
(continued)
A maintenance flag (Mtce) can appear. This flag indicates that
system-initiated maintenance tasks are in progress. To stop the
system-initiated maintenance tasks, type
>ABTK
and press the Enter key.
To return the logical drawer to service, type
>RTS
DRWR
drwr_no
and press the Enter key.
where
drwr_no
is the logical drawer number (0 to 19)
Example of a MAP response:
OSvce Tests InitiatedLCM REM1 00 0 Drwr 0 Tst PassedLCM REM1 00 0
Drwr 0 Rts Passed
If the RTS command
passed, and you must return the
other logical drawer to service
passed, and the other logical
drawer is in service
failed
Repeat step 24 for the other logical drawer in the pair.
Update table LCMDRINV.
Note: Make sure you have the new MAC address from the replacement
card as recorded in step 2.
a
To open table LCMDRINV, type
>TABLE
LCMDRINV
and press the Enter key.
b
To position on the tuple for the LCM, type
>POS
site_name
and press the Enter key.
where
site_name
is the name of the site
frame_no
is the number of the frame
Do
step 25
step 26
step 39
frame_no
lcm_no