At the MAP terminal
10
To display the cabinet location of the faulty line card, type
>CKTLOC
and press the Enter key.
Example of a MAP display:
Site Flr RPos
REM1
01
B04
GRD START
2DB LOSS
NO
Note: In the example MAP display, the line card is an NTEX17CA and the
location of the card is
Site
in the remote site
Flr
on the 1st floor
RPos
row B is the location of the line equipment bay 04
Bay_id
in line concentrating equipment, bay 01
Shf
in shelf 04
Description
in hardware device LCM, bay 01
Slot
in line drawer 01, slot 00
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Bay_id
Shf
Description
LCE
01
04
LCM
NETWORK
BAL
NO
NON LOADED
in an RSC LCM
Slot
01 0
01:00
MAN OVR SET
NO
1-747
NTEX17
(continued)
EqPEC
EX17CA

Advertisement