Nortel DMS-100 Series Replacement Procedures page 707

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

y
is the next line subgroup busied in step 8
17
Access the PM level of the MAP display and post the first LSG of the line
drawer that contains the BIC to be replaced by typing
>MAPCI;MTC;PM;LNS;LTP;POST L site frame_no unit_no lcm_dr
and pressing the Enter key.
where
site
is the name of the site at which the LCME is located
frame_no
is the number of the frame in which the LCME is located
unit_no
is the number of the LCME unit with the faulty card
lcm_dr
is the number of the drawer with the faulty card
18
Return the busied lines in the first LSG to service by typing
>RTS ALL
and pressing the Enter key.
19
Post the next LSG of the same line drawer by typing
>NEXT D
and pressing the Enter key.
20
Repeat step 18 and step 19 until all busied lines in the drawer are returned to
service.
21
Post the LCME with the LCA shelf containing the replaced card by typing
>PM;POST LCME site frame_no unit_no
and pressing the Enter key.
where
site
is the name of the site at which the LCME is located
frame_no
is the number of the frame in which the LCME is located
unit_no
is the number of the LCME unit with the faulty card
22
Return the LCME unit to service by typing
>RTS lcm_unit_no
and pressing the Enter key.
where
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC LCME
1-675
NTBX36
(continued)