Nortel DMS-100 Series Replacement Procedures page 221

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
6
To test the line card just replaced, type
>DIAG
and press the Enter key.
If the DIAG
passes
fails
7
To return the line card to service, type
>RTS
and press the Enter key.
If the RTS
passes
fails
8
Send any faulty cards for repair according to local procedure.
9
Record the following items in office records:
date the card was replaced
serial number of the card
indications that prompted replacement of the card
Go to step 11.
10
Get additional help replacing this card by contacting the personnel
responsible for a higher level of support.
11
You have correctly completed this procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 7
step 10
Do
step 8
step 10
NT6X99
in a STAR or RLD
1-189
(end)