Nortel DMS-100 Series Replacement Procedures page 991

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NTMX72 card in an RSCE RCC2
At your Current Location
1
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
2
Obtain an NTMX72 replacement card. Ensure the replacement card has the
same product engineering code (PEC), including suffix, as the card that is to
be removed.
At the MAP terminal
3
Set the MAP display to the PM level and post the RCC2 by typing
>MAPCI;MTC;PM;POST RCC2 rcc2_no
and pressing the Enter key.
where
rcc2_no
is the number of the RCC2 with the faulty card
Example of a MAP display:
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC RCC2
CAUTION
Loss of service
When replacing a card in the RCC2, ensure that the unit in
which you are replacing the card is inactive and that the mate
unit is active.
1-959
NTMX72
(continued)