Nortel DMS-100 Series Replacement Procedures page 47

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X85 card in an SMS-R
At your Current Location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product engineering code (PEC) including suffix, as the card to be removed
and the dual in-line package (DIP) switch settings are set the same as the
card being replaced.
At the MAP display
3
Access the PM level of the MAP display by typing
>MAPCI;MTC;PM;POST SMSR smsr_no
and pressing the Enter key.
where
smsr_no
is the number of the SMS-R to be posted
Example of a MAP response:
SMSR 3
Unit0
Unit1
4
Display the DS-1 links associated with the faulty DS-1 interface card by typing
>TRNSL P
and pressing the Enter key.
Record all link numbers, information on faulty links, and any protection line
information. Each 6X85 card has two ports; for instance, ports 0 and 1 are
on one 6X85 card. Look at the link, RCS location, and port numbers in the
following MAP display. The first line indicates that link 0 is routed to RCS
location BRCS 00 0. Link 0 is a protection line.
Example of a MAP response:
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
INSV
LINKS_OOS
Act
InSv
InAct
ISTb
in an SMS-R
CSIDE 0
PSIDE 1
1-15
NT6X85
(continued)