1-192 XPM card replacement procedures (continued)
NT7X05
in an RSC RCC/RCC2
Replacing an NT7X05 card in an RSC RCC
At your Current Location
1
2
At the MAP display
3
297-8021-547 Standard 14.02 May 2001
(continued)
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
CAUTION
Loss of service
When replacing a card in the RCC ensure the unit where you
are replacing the card is INACTIVE and the mate unit is
ACTIVE by observing the INSV and ACTIVE LEDs on each
NTMX77 card.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
Access the PM level and post the RCC by typing
>MAPCI;MTC;PM;POST RCC rcc_no
and pressing the Enter key.
where
rcc_no
is the number of the RCC to be busied
Example of a MAP display: