lcme_unit_no
is the number of the LCME unit busied in step 4
If RTS
passed
failed
12
Send any faulty cards for repair according to local procedure.
13
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 16.
14
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
15
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
16
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 12
step 15
NTBX35
in an RSC LCME
1-637
(end)