Nortel DMS-100 Series Replacement Procedures page 524

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-492 XPM card replacement procedures (continued)
NTBX02
in an RSC-S (PCM-30) Model A RCO2
24
At the MAP terminal
25
26
297-8021-547 Standard 14.02 May 2001
CAUTION
Loss of subscriber service
Subscriber service may be lost in the active unit when
reseating the NTBX02 card.
It is recommended that this procedure be performed during
low traffic periods.
Seat and lock the card.
a
Using your fingers or thumbs, push on the upper and lower edges of the
faceplate to ensure that the card is fully seated in the shelf.
b
Close the locking levers.
Load the DCH card by typing
>LOADPM
and pressing the Enter key.
Use the following information to determine the next step in this procedure.
If LOADPM
passed
failed
(continued)
Do
step 27
step 34