Nortel DMS-100 Series Replacement Procedures page 746

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-714 XPM card replacement procedures (continued)
NTBX72
in an RSC-S (DS-1) Model A LCME
16
17
18
19
20
21
297-8021-547 Standard 14.02 May 2001
and pressing the Enter key.
where
lcme_unit_no
is the number of the LCME unit tested in step 14
If RTS
passed
failed
Switch ringing generator activity to the new NTBX72 card by typing
>SWRG PM
and pressing the Enter key.
If SWRG
passed
failed
Send any faulty cards for repair according to local procedure.
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 21.
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
(end)
Do
step 16
step 20
Do
step 17
step 20