Replacing an NT6X92 card in an SMA2
At your current location
1
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
2
Ensure you know the physical location of the faulty card.
If card location is
known
unknown
3
Perform the procedure "Locating a faulty card in an SMA2."
4
Obtain a replacement card. Ensure the replacement card has the same
product engineering code (PEC), including suffix, as the card being removed.
At the MAP terminal
5
Ensure the current MAP display is at the PM level and post the SMA2 by
typing
>MAPCI;MTC;PM;POST SMA2 sma2_no
and pressing the Enter key.
where
sma2_no
is the number of the SMA2 being posted
Example of a MAP response
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 4
step 3
CAUTION
Loss of service
When replacing a card in the SMA2, ensure the unit in which
you are replacing the card is inactive and the mate unit is
active.
NT6X92
in an SMA2
(continued)
1-127