Nortel DMS-100 Series Replacement Procedures page 632

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-600 XPM card replacement procedures (continued)
NTBX34
in an RSC LCME
13
14
15
16
17
18
297-8021-547 Standard 14.02 May 2001
(end)
lcme_unit_no
is the number of the LCME unit busied in step 4
Use the following information to determine where to proceed.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 18.
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
Do
step 14
step 17

Advertisement

Table of Contents
loading

Table of Contents