Nortel DMS-100 Series Replacement Procedures page 69

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

15
Test the inactive unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If TST
passed
failed
16
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If RTS
passed
failed
17
Return to the maintenance procedure that directed you to this procedure. At
the point where a faulty card list was produced, identify the next faulty card
on the list and go to the appropriate card replacement procedure for that card
in this manual.
18
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
At the frame
19
Remove the sign from the active SMS unit.
20
Send any faulty cards for repair according to local procedure.
21
Record the following items in office records according to local policy:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
22
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 16
step 17
Do
step 19
step 18
NT6X86
in an SMS
(continued)
1-37