Nortel DMS-100 Series Replacement Procedures page 661

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

13
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
14
Return the LCME unit to service by typing
>RTS UNIT lcme_unit_no
and pressing the Enter key.
where
lcme_unit_no
is the number of the LCME unit tested in step 12
15
Use the following information to determine where to proceed.
If RTS
passed
failed
16
Send any faulty cards for repair according to local procedure.
17
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 20.
18
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
19
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
20
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC-S (PCM-30) Model A LCME
Do
step 18
step 14
Do
step 16
step 19
1-629
NTBX34
(end)