Nortel DMS-100 Series Replacement Procedures page 90

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-58 XPM card replacement procedures (continued)
NT6X87
in an RSC-S (DS-1) Model B LCME
Replacing an NT6X87 card in an RSC-S LCME
At your Current location
1
2
At the MAP terminal
3
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
Post the line equipment number (LEN) of the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcme _ no unit_no lsg _ no
ckt_no
and pressing the Enter key.
where
site
is the location name of the LCME with the faulty card
lcme_no
is the number of the LCME with the faulty card
unit_no
is the number of the LCME unit with the faulty card
lsg_no
is the number of the LSG with the faulty card
ckt_no
is the number of the circuit associated with the faulty card
Example of a MAP response:
(continued)

Advertisement

Table of Contents
loading

Table of Contents