Nortel DMS-100 Series Replacement Procedures page 728

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-696 XPM card replacement procedures (continued)
NTBX36
in an RSC-S (DS-1) Model B LCME
22
23
24
25
26
27
28
297-8021-547 Standard 14.02 May 2001
frame_no
is the number of the frame in which the LCME is located
unit_no
is the number of the LCME unit with the faulty card
Test the LCME unit by typing
>TST UNIT lcm_unit_no
and pressing the Enter key.
where
lcm_unit_no
is the number of the LCME unit posted in step 21
If TST
passed
failed
Return the LCME unit to service by typing
>RTS lcm_unit_no
and pressing the Enter key.
where
lcm_unit_no
is the number of the LCME unit tested in step 22
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 28.
Return to the alarm clearing or other procedure that directed you to this
procedure. If necessary, go to the point where the faulty card list was
produced, identify the next faulty card on the list and go to the appropriate
card replacement procedure for that card in this manual.
Obtain further assistance in replacing this card by contacting personnel
responsible for a higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
(end)
Do
step 23
step 26
Do
step 24
step 27