in an RSC-S (PCM-30) Model A RCO2
27
Return the DCH card to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
28
Leave the DCH level of the MAP display and return to the RCO2 level by
typing
>QUIT
and pressing the Enter key.
29
Return to service the PM unit busied in step 11 by typing
>RTS unit unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCO2 unit (0 or 1) containing the new
BX02 card
30
Ensure that the RCO2 unit is in service by typing
>QUERYPM FLT
and pressing the Enter key.
Example of a MAP display:
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up