Nortel DMS-100 Series Replacement Procedures page 447

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

in an RSC-S (PCM-30) Model B RCO2
14
Use the following information to determine where to proceed.
If LOADPM
passed
failed
15
Test the inactive unit by typing
>TST UNIT rco2_unit_no
and pressing the Enter key.
where
rco2_unit_no
is the number of the RCO2 unit loaded in step 13
16
Use the following information to determine where to proceed.
If TST
passed
failed
17
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
18
Return the inactive RCO2 unit to service by typing
>RTS UNIT rco2_unit_no
and pressing the Enter key.
where
rco2_unit_no
is the number of the RCO2 unit tested in step 15
19
Use the following information to determine where to proceed.
If RTS
passed
failed
20
Send any faulty cards for repair according to local procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up