in an RSC-S (PCM-30) Model A RCO2
16
After replacing the faulty card, load the inactive RCO2 unit by typing
>LOADPM
and pressing the Enter key.
where
unit_no
is the number of the inactive RCO2 unit
If LOADPM
passed
failed
17
Test the inactive unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCO2 unit
If TST
passed
failed
18
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
19
Return the inactive RCO2 unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCO2 unit
If RTS
passed
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
UNIT
unit_no
Do
step 17
step 24
Do
step 18
step 23
Do
step 23
step 19
Do
step 20
1-991
NTMX72
(continued)