Nortel DMS-100 Series Replacement Procedures page 721

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NTBX36 card in RSC-S LCME
At your Current Location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or were directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC) including suffix, as the card that is to be
removed.
At the MAP terminal
3
Access the LTP level and post the first line subgroup (LSG) of the line drawer
that contains the bus interface card (BIC) to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site frame_no unit_no lcm_dr
LSG
and pressing the Enter key.
where
site_
is the name of the site at which the LCME is located
frame_no
is the number of the frame in which the LCME is located
unit_no
is the number of the LCME unit with the faulty card
lcm_dr
is the number of the drawer with the faulty card
4
Busy all lines in the first LSG by typing
>BSY ALL
and pressing the Enter key.
5
Post the next LSG of the same line drawer by typing
>NEXT D
and pressing the Enter key.
6
Repeat steps 4 and 5 until all LSGs of the same line drawer are busied.
7
Post the LCME with the LCA shelf containing the card to be replaced by
typing
>PM;POST LCME site frame_no unit_no
and pressing the Enter key.
where
site
is the name of the site at which the LCME is located
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC-S (DS-1) Model B LCME
1-689
NTBX36
(continued)