The system runs a pre-SWACT audit to determine the ability of the inactive
unit to accept activity reliably.
Note: A maintenance flag appears when maintenance tasks are in
progress. Wait until the flag disappears before proceeding with the next
maintenance action.
If the message is
SWACT passed
SWACT failed
SWACT failed Reason: XPM
SWACTback
SWACT refused by SWACT
controller
7
Return to the Alarm Clearing Procedure , to clear the alarm condition on the
inactive unit. When the alarm is cleared, return to step 1 of this procedure.
At the frame
8
Put a sign on the active unit bearing the words Active unit—Do not touch.
At the MAP display
9
Busy the inactive SMS-R unit by typing
>BSY INACTIVE
and pressing the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 8
step 7
step 7
step 7
NT7X05
in an SMS-R
(continued)
1-247