Nortel DMS-100 Series Replacement Procedures page 196

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-164 XPM card replacement procedures (continued)
NT6X99
in an RSC LCM
Replacing an NT6X99 in an LCM
1
At the MAP terminal
2
297-8021-547 Standard 14.02 May 2001
(continued)
Obtain a replacement card.
Ensure that the replacement card has the same product equipment code
(PEC), including suffix, as the card to be removed.
Access the line test position (LTP) level of the MAP display and post the line
associated with the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm_no lsg_no ckt_no
and pressing the Enter key.
where
site
is the name of the site where the RSC LCM is located
lcm_no
is the number of the RSC LCM with the faulty card
lsg_no
is the number of the line subgroup with the faulty card
ckt_no
is the number of the circuit associated with the faulty card
Example of a MAP display:
CM
MS
IOD
.
.
.
LTP
0 Quit
Post
2 Post_
3
LCC PTY RNG....LEN.. ...
4
CKT TYPE FL REM1 00 0 03 03
5 BSY
6 RTS
7 DIAG
8
9 AIMStat
10 CKTLOC
11 Hold
12 Next_
13
14
15
16 Prefix
17 LCO
18 Level
Net
PM
CCS
LNS
.
.
.
DELQ
BUSYQ
DN
IBERT
Trks
Ext
.
.
.
PREFIX
STA F S LTA TE RESULT
SB
Appl
.

Advertisement