Nortel DMS-100 Series Replacement Procedures page 1000

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-968 XPM card replacement procedures (continued)
NTMX72
in an RSC-S (DS-1) Model A RCC2
Replacing an NTMX72 card in an RSC-S RCC2
At your Current Location
1
2
At the MAP terminal
3
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
CAUTION
Loss of service
When replacing a card in the RCC2, ensure that the unit in
which you are replacing the card is inactive and that the mate
unit is active.
Obtain an NTMX72 replacement card. Ensure the replacement card has the
same product engineering code (PEC), including suffix, as the card that is to
be removed.
Set the MAP display to the PM level and post the RCC2 by typing
>MAPCI;MTC;PM;POST RCC2 rcc2_no
and pressing the Enter key.
where
rcc2_no
is the number of the RCC2 with the faulty card
Example of a MAP display:
(continued)