unit_no
is the number of the RCC2 unit (0 or 1) tested in step 15
If the RTS
passed
failed
17
Load the inactive NT7X05 card by typing
>XPMSTOR INACTIVE CC load_file _name
and pressing the Enter key.
where
load_file_name
is the name of the file datafilled in field LOAD of the inventory table.
The default load_file_name is the file currently datafilled.
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.
If load
passed
failed
18
Send any faulty cards for repair according to local procedure.
19
Record the following items in office records:
•
date the card was replaced
•
serial number of the card
•
symptoms that prompted replacement of the card
Go to step 21.
20
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.
21
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC-S (DS-1) Model B RCC2
Do
step 17
step 20
Do
step 18
step 20
1-215
NT7X05
(end)