Nortel DMS-100 Series Replacement Procedures page 788

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-756 XPM card replacement procedures (continued)
NTEX17
in an RSC-S (DS-1) Model A LCME
LCC PTY RNG .....LEN..........
1FR
7
8
9
LCC PTY RNG .....LEN..........
1FR
At the MAP terminal
10
297-8021-547 Standard 14.02 May 2001
Example of a MAP display:
REM1 01 0 01 01
Determine the state of the posted line.
If the state of the line
is CPB, CPD
is CUT, HAZ, IDL, LO, PLO, SB step 9
is MB
is NEQ
is DEL, DMB, INB, LMB
Wait until the line state changes. Go to step 7.
To manually busy the line circuit, type
>BSY
and press the Enter key.
Example of a MAP display:
HOST 01 0 01 01
Note: Observe that the state that appears under the STA header changed
to MB.
If BSY command
passed
failed
To display the cabinet location of the faulty line card, type
>CKTLOC
and press the Enter key.
Example of a MAP display:
(continued)
DN
STA F S LTA
621 1134 IDL
Do
step 8
step 10
To determine why the
component is offline or not
equipped,
company personnel. Continue
as directed by operating
company personnel.
step 19
DN
STA F S LTA
621 1134 MB
Do
step 10
step 19
TE
RESULT
consult
operating
TE
RESULT