Nortel DMS-100 Series Replacement Procedures page 835

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP terminal
5
To access the peripheral module (PM) level of the MAP (maintenance and
administration position) display and post the LCM, type
>MAPCI;MTC;PM;POST LCM site frame_no lcm_no
and press the Enter key.
where
site
is the PM location (alphanumeric)
frame_no
is the equipment frame number (00 to 511)
lcm_no
is the number of the LCM (0 or 1)
Example of a MAP display:
LCM REM1 01 1 ISTb Links OOS: Cside 0 Pside 0Unit0: ISTb
/RG: 0Unit1: ISTb Mtce
11 11 11 RG: Pref 1 InSvDrwr: 01 23 45 67 89 01 23 45 67 89
0 InSv
.. .. .. .. MM .. .. .. .. ..
6
Record the numbers of the logical drawers for the NTEX54.
Note: Logical drawers configure in pairs for the physical drawer. The
NTEX54 services the physical drawer. Both logical drawers must be
manually busy to perform this card replacement procedure.
7
Check the state of the affected logical drawers.
If the state for
one or both logical drawers is
I,S, or . (dot)
both logical drawers is M
one or both logical drawers is 0
or -
8
To manually busy the logical drawer, type
>BSY DRWR drwr_no
and press the Enter key.
where
drwr_no
is the logical drawer number (0 to 23)
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC LCM
/RG: 1 Ring gen Test
Do
step 8
step 11
Determine why the drawer is of-
fline. If necessary, contact the
next level of support.
1-803
NTEX54
(continued)
11 11
Stby