At the MAP terminal
15
Load the inactive SMA unit by typing
>LOADPM INACTIVE
and pressing the Enter key.
where
unit_no
is the number of the busied SMA unit
If load
passed
failed
16
Return the inactive SMA unit to service by typing
>RTS INACTIVE
and pressing the Enter key.
where
unit_no
is the number of the SMA unit loaded in step 15
If RTS
passed
failed
At the equipment frame
17
Remove the sign from the active SMA unit.
18
Go to the common returning a card procedure in this document.
Go to step 20.
19
For further assistance, contact the personnel responsible for the next level of
support.
20
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
21
For further assistance with switch of activity, contact the personnel
responsible for the next level of support.
Note: If the system recommends using the SWACT command with the
FORCE option, consult office personnel to determine if use of the FORCE
option is advisable.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 16
step 19
Do
step 17
step 19
1-117
NT6X92
in an SMA
(end)