Nortel DMS-100 Series Replacement Procedures page 852

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-820 XPM card replacement procedures (continued)
NTEX54
in an RSC-S (DS-1) Model A LCME
At the MAP terminal
5
6
7
8
297-8021-547 Standard 14.02 May 2001
To access the peripheral module (PM) level of the MAP (maintenance and
administration position) display and post the LCM, type
>MAPCI;MTC;PM;POST LCM site frame_no lcm_no
and press the Enter key.
where
site
is the PM location (alphanumeric)
frame_no
is the equipment frame number (00 to 511)
lcm_no
is the number of the LCM (0 or 1)
Example of a MAP display:
LCM REM1 01 1 ISTb Links OOS: Cside 0 Pside 0
Unit0: ISTb
Unit1: ISTb Mtce
Drwr: 01 23 45 67 89 01 23 45 67 89
.. .. .. .. MM .. .. .. .. ..
Record the numbers of the logical drawers for the NTEX54.
Note: Logical drawers configure in pairs for the physical drawer. The
NTEX54 services the physical drawer. Both logical drawers must be
manually busy to perform this card replacement procedure.
Check the state of the affected logical drawers.
If the state for
one or both logical drawers is
I,S, or . (dot)
both logical drawers is M
one or both logical drawers is 0
or -
To manually busy the logical drawer, type
>BSY DRWR drwr_no
and press the Enter key.
where
drwr_no
is the logical drawer number (0 to 23)
(continued)
/RG: 0
/RG: 1 Ring gen Test
11 11
11 11 11 RG: Pref 1 InSv
Do
step 8
step 11
Determine why the drawer is of-
fline. If necessary, contact the
next level of support.
Stby
0 InSv