1-224 XPM card replacement procedures (continued)
NT7X05
in an RSC-S (PCM-30) Model A RCO2
16
17
18
19
20
297-8021-547 Standard 14.02 May 2001
unit_no
is the number of the RCO2 unit (0 or 1) tested in step 14
If TST
passed
failed
Load the inactive RCO2 unit by typing
>XPMSTOR INACTIVE CC [load_file_name]
and pressing the Enter key.
where
load_file_name
is the name of the file datafilled in field, LOAD, of the inventory table.
If load
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 20.
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
(end)
Do
step 16
step 19
Do
step 17
step 19