1-974 XPM card replacement procedures (continued)
NTMX72
in an RSC-S (DS-1) Model A RCC2
18
19
20
21
22
23
24
25
297-8021-547 Standard 14.02 May 2001
If load
failed
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
Return the inactive RCC2 unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCC2 unit
If RTS
passed
failed
Remove the sign from the active RCC2 unit.
Send any faulty cards for repair according to local procedure.
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 25.
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
(end)
Do
step 24
Do
step 23
step 19
Do
step 20
step 24