29
From the pop-up menu select Describe/Modify Object. The Object
Description dialog box appears.
30
From the Object Description dialog box, select HSTP Application from the
fields under Object Attributes.
31
Select View/Modify Object Attributes.
32
Enter the new MAC address in the %LAC MAC Address field, for example,
0060381120a1.
33
Click the Verify button to verify the information.
34
Click the OK button to close the Attributes dialog box.
35
Click OK to close the Object Description dialog box.
36
Place the cursor on the DBIC you want to return to service and use the mouse
to select
Maintenance -> DBIC -> Rts
from the pop-up menu.
37
Send any faulty cards for repair according to local procedure.
38
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 40.
39
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
40
You have successfully completed this card replacement procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
1-799
NTEX54
in an RLCM
(end)