1-854 XPM card replacement procedures (continued)
NTEX54
in a STAR
(continued)
At the MAP terminal
5
6
7
8
297-8021-547 Standard 14.02 May 2001
To access the peripheral module (PM) level of the MAP (maintenance and
administration position) display and post the STAR, type
>MAPCI;MTC;PM;POST STAR site frame_no unit_no
and press the Enter key.
where
site
is the site name (alphanumeric) of the STAR
frame_no
is the equipment frame number (00 to 511) of the STAR
unit_no
is 0 for the STAR
Example of a MAP display:
STAR REM1 O1 1 ISTb Links_OOS: CSide 0 PSide 0 UMP OOS: 0
Unit
0: InSv Mtce
Unit 1: InsV Mtce
/RG: 0
11 11 11 11 11 22 22 22 22 22 33 33 33 Pref 0 InSv
01 23 45 67 89 01 23 45
.. .. SS .. .. .. .. ..
Record the numbers of the logical drawers for the NTEX54.
Note: Logical drawers configure in pairs for the physical drawer. The
NTEX54 services the physical drawer. Both logical drawers must be
manually busy to perform this card replacement procedure.
Check the state of the affected logical drawers.
If the state for
one or both logical drawers is
I,S, or . (dot)
both logical drawers is M
one or both logical drawers is 0
or -
To manually busy the logical drawer, type
>BSY DRWR drwr_no
and press the Enter key.
where
/RG: 0
RG
67 89 01 23 45 67 89 01 23 45 Stby 1 InSv
.. .. .. .. .. .. .. .. .. ..
Do
step 8
step 11
Determine why the drawer is
offline. If necessary, contact the
next level of support.