Nortel DMS-100 Series Replacement Procedures page 193

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
6
Test the line card just replaced by typing
>DIAG
and pressing the Enter key.
If the DIAG
passed
failed
7
Return the line card to service by typing
>RTS
and pressing the Enter key.
If the RTS
passed
failed
8
Send any faulty cards for repair according to local procedure.
9
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 11.
10
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
11
You have successfully completed this procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
Do
step 7
step 10
Do
step 8
step 10
1-161
NT6X99
in an RLCM