Nortel DMS-100 Series Replacement Procedures page 1037

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

PM
SMA2
SMA2
Unit0:
Unit1:
6
Observe the MAP display and determine if the faulty card is in the active or
the inactive unit.
If faulty card is on
active unit
inactive unit
7
Switch the processing activity (SWACT) to the inactive unit by typing
>SWACT
and pressing the Enter key.
A confirmation prompt for the SWACT command is displayed at the MAP
terminal.
If prompt indicates
cannot continue at this time
can continue at this time
8
Reject the prompt to SWACT of the units by typing
>NO
and pressing the Enter key.
The system discontinues the SWACT.
9
Confirm the system prompt by typing
>YES
and pressing the Enter key.
The system runs a pre-SWACT audit to determine the ability of the inactive
unit to accept activity reliably.
Note: A maintenance flag appears when maintenance tasks are in
progress. Wait until the flag disappears before proceeding with the next
maintenance action.
If the message is
SWACT passed
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
SysB
ManB
3
0
0
0
0 ISTb
Links_OOS:
Act
InSv
InAct IsTb
in an SMA2
OffL
CBsy
1
0
0
0
CSide
0, PSide
Do
step 7
step 11
Do
step 8
step 9
Do
step 11
1-1005
NTMX72
(continued)
ISTb
InSv
2
13
1
7
0

Advertisement

Table of Contents
loading