1-628 XPM card replacement procedures (continued)
NTBX34
in an RSC-S (PCM-30) Model A LCME
At the MAP terminal
9
10
11
12
297-8021-547 Standard 14.02 May 2001
Load the LCME unit by typing
>loadpm unit unit_no CC
and pressing the Enter key.
where
unit_no
is the number of the LCME unit busied in step 4
Use the following information to determine where to proceed.
If load
passed
failed
Test the LCME unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the LCME unit loaded in step 9
Use the following information to determine where to proceed.
If TST
passed
failed
(continued)
Do
step 11
step 19
Do
step 13
step 18