1-858 XPM card replacement procedures (continued)
NTEX54
in a STAR
(continued)
Relationship of line drawer to FSP fuse numbers (Sheet 2 of 2)
12
13
297-8021-547 Standard 14.02 May 2001
Line drawer
15
16
17
18
Identify the drawer. Press the small thumb-latch button on the lower left edge
of the drawer. Pull the drawer out. To secure the drawer in a steady
horizontal position, tip the drawer until the catch rests on the line drawer track.
Catch
Line drawer
Thumb-latch
button
Disconnect the data cable from the RJ-45 connector on the DBIC. The RJ-45
connector is located at slot position 16 of the odd LSG (connector slot). Refer
to the following figure.
FSP FUSE numbers
+5 V
+15 V
15
15
16
16
17
17
18
18
-48 V
15
16
17
18