1-960 XPM card replacement procedures (continued)
NTMX72
in an RSC RCC2
4
5
6
297-8021-547 Standard 14.02 May 2001
(continued)
CM
MS
IOD
Net
.
.
.
RCC2
SysB
0 Quit
PM
2 Post_
RCC2
3 ListSet
4
RCC2
0 ISTb
5 TRNSL
Unit0:
Inact InSv
6 TST
Unit1:
Act InSv
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13
14 QueryPM
15
16
17
18
By observing the MAP display, be sure that the card that is to be removed is
on the inactive unit.
Busy the inactive PM unit by typing
>bsy INACTIVE
and pressing the Enter key.
Example of a MAP response:
RCC2
0 ISTb
Unit0:
Inact ManB
Unit1:
Act
bsy unit 0
RCC2 0 Unit 0
If the BSY command
passed
failed
Reset the inactive RCC2 unit by typing
>PMRESET
UNIT
and pressing the Enter key.
where
PM
CCS
LNS
.
.
.
.
ManB
OffL
0
0
0
0
0
0
Links_OOS:
CSide
Links_OOS: CSide
ISTb
Bsy Passed