Nortel DMS-100 Series Replacement Procedures page 1036

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-1004 XPM card replacement procedures (continued)
NTMX72
in an SMA2
(continued)
Replacing an NTMX72 card in an SMA2
At your current location
1
2
3
4
At the MAP terminal
5
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Ensure you know the physical location of the faulty card.
If card location is
known
unknown
Perform the procedure "Locating a faulty card in an SMA2."
CAUTION
Loss of service
When replacing a card in the SMA2, ensure the unit in which
you are replacing the card is inactive and the mate unit is
active.
Obtain an NTMX72 replacement card. Ensure the replacement card has the
same product engineering code (PEC), including suffix, as the card to be
removed.
Ensure the current MAP display is at the PM level and post the SMA2 by
typing
>MAPCI;MTC;PM;POST SMA2 sma2_no
and pressing the Enter key.
where
sma2_no
is the number of the SMA2 with the faulty card
Example of a MAP display:
Do
step 4
step 3