Nortel DMS-100 Series Replacement Procedures page 710

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-678 XPM card replacement procedures (continued)
NTBX36
in an RSC-S (DS-1) Model A LCME
Summary of card replacement procedure for an NTBX36 card in RSC-S LCME
At LTP MAP level,
BSY all lines
associated with BIC
At PM MAP level,
BSY associated
LCA
Remove –48, +5,
and +15 V fuses
Put on wriststrap
Replace the BIC
card with one of
same PEC code
297-8021-547 Standard 14.02 May 2001
(continued)
Replace –48, +5,
and +15 V fuses
Directed here
Y
from another
procedure?
N
Return LCA to
service
Return all busied
lines to service
End of procedure
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Return to original
procedure