Nortel DMS-100 Series Replacement Procedures page 985

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

RCO2 0
Please confirm ("YES", "Y", "NO", or "N"):
If the system
prompts you to confirm a warm
SWACT
rejects the SWACT
7
To confirm the command, type:
>YES
and press the Enter key.
Example of a MAP response:
Unit0:
Unit1:
RCO2 0
If the MAP response
is SWACT passed
other than listed here
8
A maintenance flag (Mtce) can appear. A maintenance flag indicates
system-initiated maintenance tasks are in progress. Wait until the flag
disappears from the status lines for both RCO2 units before you proceed to
the next step.
At the cabinet
9
Place a sign with the words Active unit-Do not touch on the active unit. Do
not attach this sign with magnets or tape.
10
To manually busy (ManB) the inactive unit, type:
>BSY
INACTIVE
and press the Enter key.
Example of a MAP response:
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
A Warm SwAct will be performed after
data sync of active terminals.
Inact SysB
Mtce
Act
ISTb
SwAct Passed
in an RSC-M
Do
step 7
step 24
Do
step 8
step 23
1-953
NTMX72
(continued)

Advertisement

Table of Contents
loading

Table of Contents