Nortel DMS-100 Series Replacement Procedures page 382

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-350 XPM card replacement procedures (continued)
NTAX74
in an SMA2
(continued)
SMA2
SMA2 0 ISTb
Unit0:
Unit1:
6
7
8
9
297-8021-547 Standard 14.02 May 2001
SysB
ManB
PM
3
0
SMA2
0
0
Links_OOS:
Act
InSv
Inact SysB
Observe the MAP display and determine if the faulty card is in the active or
the inactive unit.
If the faulty card is in the
active unit
inactive unit
SWACT the units by typing
>SWACT
and pressing the Enter key.
A confirmation prompt for the SWACT command is displayed at the MAP
terminal.
If SWACT
cannot continue at this time
can continue at this time
Reject the prompt to SWACT the units by typing
>NO
and pressing the Enter key.
The system discontinues the SWACT.
Confirm the system prompt by typing
>YES
and pressing the Enter key.
The system runs a pre-SWACT audit to determine the ability of the inactive
unit to accept activity reliably.
Note: A maintenance flag appears when maintenance tasks are in
progress. Wait until the flag disappears before proceeding with the next
maintenance action.
If the message is
SWACT passed
Offl
CBsy
ISTb
1
0
2
0
0
1
CSide 0, PSide 0
Do
step 7
step 11
Do
step 8
step 9
Do
step 11
InSv
13
7

Advertisement

Table of Contents
loading

Table of Contents