Nortel DMS-100 Series Replacement Procedures page 620

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-588 XPM card replacement procedures (continued)
NTBX27
in a STAR or RLD
Replacing an NTBX27 card in a STAR or RLD
At your current location
1
2
At the MAP terminal
3
4
297-8021-547 Standard 14.02 May 2001
(continued)
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Get a replacement card. Make sure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
To post the LEN of the card to be replaced, type
>mapci;mtc;lns;ltp;post l site frame unit lsg ckt
and press the Enter key.
where
site
is the name of the site where the STAR is located
frame
is the frame number of the STAR with the faulty card (0 to 511)
unit
is 0 for the STAR
lsg
is the number of the line subgroup with the faulty card (0 to 35)
ckt
is the number of the circuit associated with the faulty card (0 to 31)
Example of a MAP display:
Post
DELQ
LCC PTY RNG....LEN......DN
ISDN Loop
HOST 00 0 03 03
To busy the NTBX27 line card, type
>BSY
and press the Enter key.
Example of a MAP display:
Post
DELQ
LCC PTY RNG....LEN......DN
ISDN Loop
HOST 00 0 03 03 4931082
BUSYQ
PREFIX
STA F S LTA TE RESULT
4931082
BUSYQ
PREFIX
STA F S LTA TE RESULT
MB
IDL

Advertisement