Nortel DMS-100 Series Replacement Procedures page 963

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the equipment frame
26
Remove the sign from the active SMA unit.
27
Send any faulty cards for repair according to local procedure.
28
Note the following in the office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 30.
29
For further assistance, contact the personnel responsible for the next level of
support.
30
You have completed this procedure. Return to the maintenance procedure
that directed you to this card replacement procedure and continue as
directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an SMA-MVI-20
1-931
NTMX71
(end)