1-346 XPM card replacement procedures (continued)
NTAX74
in an SMA-MVI-20
42
At the equipment frame
43
44
45
46
47
48
297-8021-547 Standard 14.02 May 2001
(end)
and pressing the Enter key.
If LOADFW UPGRADE
passed
failed
Return the inactive SMA unit to service by typing
>RTS INACTIVE
and pressing the Enter key.
If RTS
passed
failed
Remove the sign from the active SMA unit.
Send any faulty cards for repair according to local procedure.
Note the following in the office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 48.
Return to the Alarm Clearing Procedure or other procedure that directed you
to this procedure. If necessary, go to the point where the faulty card list was
produced, identify the next faulty card on the list, and go to the appropriate
procedure for that card in this manual.
For further assistance, contact the personnel responsible for the next level of
support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.